Gate Valve non Rising IRGA-NRS-F3

Categories:
Body Material:

Description

Specification Standards :

  • Design standard : EN 1171; BS 5163
  • Flange as standard : EN 1092-2
  • Face to face dimensios : EN 558-1 Series 3
  • Test standard : EN 12266

Features :

  • Non rising stem
  • Resilient seat
  • Hand wheel operator
  • Test Requirements
Test Requirement 
Working Pressure150 PSI(10Bar )
Maximum Pressure200 PSI ( 14 Bar )
Shell Teat Pressure300 PSI (21 Bar)
Applicable Temperature<1200C

Materials :

No.PartsMaterial
1Stem2Cr13
2“O” RingNBR
3“O” Ring 3NBR
4GasketNylon
5Stem nutBrass
6BonnetGGG50
7WedgeGGG50+EPDM
8Middle gasketNBR
9BoltsSteel8.8+Wax
10BodyGGG50