www.valvearita.com

Y-Strainer Valve IYS-S200

Category Tag

Specification Standards 

  • Pipe Threaded end in accordance with BSPT

Features :
 

  • Is a device which provides a mean to remove debris form a flowing fluid in pipeline.
  •  A perforated screen or mesh is used to trap the debris in the strainer chamber.
  • The strainer chamber is designed with a plug or cover that can be easily removed for maintenance purposes.
  • The y-strainer can be installed either in horizontal or vertical down position and must be always before the valve or equipment.

Application : 

  • For general and industrial services
  • Applicable medium : water , light oil , steam

Materials :

Parts Material
Gasket Non – asbestos
Body/cap Cast iron (FC200)
Screen SS304

Test Requirements :

  • Working Pressure : 150 psi
  • Maximum Pressure : 200 psi
  •  Shell Test Pressure : 300 psi
  • Applicable Temperature : < 200 °C

Screen Dimensions : mm.

Size A P Thickness
1/2″ to 2″ 1.5 3.5 0.5

Dimensions : mm.

Size 1/2″ 3/4″ 1″ 1.1/4″ 1.5″ 2″
D 15 20 25 32 40 50
H 62 75 86 98 107 122
L 90 105 125 148 163 180
Cv 20 40 66 120 195 310
Wt(kg) 0.54 0.88 1.37 2.22 2.70 4.14